RobustelGoRuggedM1000ProUserGuide
RT_M1000Pro_UG_v01.01 27.12.2011 11/59
Confidential
RS‐485 Data+(A),Data‐(B),GND
DigitalInput
Type DryContact
Mode DIoreventcounter
DryContact
On:shorttoGND
Off:open
Isolation 3KVDCor2KVrms
CounterFrequency 900Hz
DigitalFilteringTimeInterval Softwareselectable
Over ‐voltageProtection 36VDC
DigitalOutput
Type Sink
Mode DOorpulseoutput
PulseOutputFrequency 1kHz
Over ‐voltageProtection 40VDC
Over ‐currentProtection 0.5A
Isolation 3KVDCor2KVrms
LEDIndicators LEDIndicators 6LEDindicators,PWR,RUN,NETand3levelRSSI
RTC RealTimeClock Built‐inrealtimeclockwithbuttonbattery
Watchdog WatchdogandTimer Built‐inwatchdogandtimer
Switch Switch ConfigurationmodeandNormalmodeselectingbyswitch
PowerSupply
Interface
PowerSupplyInterface 2‐pin5mmpluggableterminalblock
PowerRequirements
InputVoltage 9to36VDC
PowerConsumption
Idle:50‐60mA@12V
DataLink:100to200mA(peak)@12V
Physical
Characteristics
Housing Metal
Weight 300g
Dimension
Withoutears(LxWxH):102.4x71.4x29.4mm
Withears(LxWxH):102.4x99.4x29.4mm
InstallationMethod 35mmDin‐Railorwallmountingordesktop
Environmental
Limits
OperatingTemperature‐25to70°C
StorageTemperature‐40to85°C
OperatingHumidity 5to95%RH
RegulatoryandType
Approvals
Directives RoHSandWEEEcompliant
CEandR&TTEApproval Q12012
Warranty WarrantyPeriod 1year