RobustelGoRuggedM1000ProUserGuide
RT_M1000Pro_UG_v01.01 27.12.2011 26/59
Confidential
Mode @
Connection
Control
Selectfrom“AlwaysOnline”and“ConnectOnDemand”.
AlwaysOnline:M1000Prowillautomaticallya GPRS connectionafterpoweronandeach
restarts,thiswillremainandwillbere‐establishedafteraninterruption.
Connect On Demand: After selection this option, user could configure wakeup at preset
time,wakeupbyCall,wakeupbySMS,wakeupbylocalserialportdataatWakeupTab.
Always
Online
Shut Down
Module
WhenIdle
Ticktoenable.
Enable:onlyavailable whenenable“Inactivity Time”under“ConnectOnDemand”mode.
WhenM1000ProautodisconnectGPRS,themodulewillenter“shutdown”modetosave
power.
Disable:M1000Prowillnot“shutdown”modulewhenautodisconnectGPRS.
Note:
M1000 Pro can only be wakeup by serial data/presettime/periodically when enable shut
downmodule,alsoSMScontrolisnotavailableunderthis mode.
M1000 Pro can be wakeup by serial data/preset ti me/periodically/SMS/Caller ID when
disableshutdownmodule.
Disable
Interactivity
Time
Usercould configurethisfieldaftersetting M1000Pro underConnectOnDemandmode,
inputfrom5to1200seconds.
ThisfieldspecifiestheidletimesettingforGPRSauto‐disconnection.
120
seconds
MaxRetries
The maximum retries times for automatically re‐connect when M1000 Pro fails
communicatingtopeerviaTCPorUDP,inputfrom1to60.
After maximum retries, M1000 Pro will restart the built‐in wireless module, such as
CinterionMC55i.ThenM1000Prowillre‐connectagainwithmaximumretries.
Whenconnectingsuccessful,theMaxRetriescounterwillsetto0.
5
Connect
Interval
M1000Prowillautomaticallyre‐connectwiththisintervalwhenitfailscommunicatingto
peerviaTCPorUDP,inputfrom10to1200seconds.
60